Description:
This device can monitor such parameters as ECG, RESP, SpO2, PR, NIBP and dual-channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. At the same time, its built-in replaceable battery provides convenience for patient moving.
Functions
- Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP, ETCO2, IBP
- ECG Heart rate(HR)
- ECG waveform
- Arrhythmia and ST-segment analysis
- RESP Respiration rate(RR)
- Respiration waveform
- SpO2 Pulse oxygen saturation(SpO2)
- Plethysmogram(PLETH) waveform
- Pulse rate(PR)
- Bar graph
- NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
- TEMP T1, T2, TD
- It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.
Features:
- 12.1'' TFT color LCD, 15-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakhstan, Polish, Czech).
- Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
- All-round monitor for adult, pediatric and neonate.
- With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.
- Waveform, parameter color and location can be set optionally.
- Operation mode: keys and buttons.
- Display up to 8-channel waveform on one screen.
- Display 7-lead ECG waveform on one screen, and with ECG step function.
- Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
- HRV analysis function.
- NIBP measurement mode: Manual/AUTO/Continuous, storage for 4800-group NIBP data.
- Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
- Drug concentration calculation and titration table functions.
- Print trend table data with one-key.
- Connect to Central Monitoring System by 3G, WiFi or wired mode.
- AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
- Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).
Performance:
ECG
- Lead mode: 3-lead or 5-lead
- Lead selection: I, II, III, aVR, aVL, aVF, V
- Waveform: 5-lead, 2-channel
- 3-lead, 1-channel
- Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
- Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
HR:
- Measurement and alarm range: 15~350bpm
- Accuracy: ±1% or ±1bpm, whichever is greater
- Alarm accuracy: ± 2 bpm
- Resolution: 1 bpm
- ST-segment monitoring:
- Measurement and alarm range: -2.0mV~+2.0mV
- Accuracy: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is greater
- Other range: unspecified
- Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
- Pacemaker: yes
RESPIRATION
- Method: R-F(RA-LL) Impedance
- Respiration rate:
- Measurement and alarm range: 0~150rpm
- Resolution: 1 rpm
- Measurement accuracy: ±2 rpm
- Alarm accuracy: ±3 rpm
- Apnea alarm: 10~40s
- Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
NIBP
- Method: Oscillometry
- Mode: Manual/AUTO/Continuous
- Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes
- Measurement period in Continuous mode: 5 minutes
- Measurement and alarm range: 10 ~ 270 mmHg
- Resolution: 1 mmHg
- Cuff pressure accuracy: ±3 mmHg
- Measurement accuracy:
- Maximal mean deviation: ±5 mmHg
- Maximal standard deviation: 8mmHg
- Over-pressure protection:
- Adult mode: 297±3 mmHg
- Pediatric mode: 240±3 mmHg
- Neonatal mode: 147±3 mmHg
SpO2
- Measurement and alarm range: 0 ~ 100%
- Resolution: 1%
- Measurement accuracy: 70%~100%: ±2%;
- 0%~69%: unspecified
PR
- Measurement and alarm range: 30 ~ 250 bpm
- Measurement accuracy: ±2 bpm or ±2%, whichever is greater
TEMP
- Channel: dual-channel
- Measurement and alarm range: 0 ~ 50℃
- Resolution: 0.1 ℃
- Accuracy: ±0.1 ℃
EtCO2
- Method: Sidestream or Mainstream
- Measurement range for CO2: 0~150mmHg
- Resolution for CO2:
- 0 ~ 69 mmHg: 0.1 mmHg
- 70 ~ 150 mmHg: 0.25 mmHg
- Accuracy for CO2:
- 0 ~ 40 mmHg: ±2 mmHg
- 41 ~ 70 mmHg: ±5%
- 71 ~ 100 mmHg: ±8%
- 101 ~ 150 mmHg: ±10%
- AwRR range: 2~150 rpm
- AwRR accuracy: ±1 rpm
- Apnea alarm: yes
IBP
- Channel: dual-channel
- Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
- Measurement and alarm range: -10~300 mmHg
- Resolution: 1 mmHg
- Accuracy: ±2% or 1mmHg, whichever is greater
- Power supply:AC 100-240V, 50/60Hz
- Safety classification: Class I, type CF defibrillation-proof applied part
Accessories
- Adult fingertip SpO2 probe (5-pin)
- Adult NIBP cuff
- NIBP extension tube
- ECG lead cable
- ECG electrode
- Temperature probe
- Power cord
- User Manual (GB only)on request for other Language
- CO2 module
- IBP module
- Print paper
Physical characteristic:
- Dimension: 319 mm(L) × 161 mm(W) × 269 mm(H)
- Weight: 3.6 Kg
Lead time:
Our lead times are 5-7 working days excluding weekends, public holiday’s & shipping time with our courier.
Lead times on out of stock or special-order items 6-8 weeks / 8-10 weeks
PLEASE NOTE DUE TO UNFORSEEN ROAD OR AIR FREIGHT DELAYS PARECELS CAN BE DELAYED BY A FEW DAYS.
*Please note pictures are mainly for illustration purposes, actual product and size may vary slightly*