Contec MS400 Multi-Parameter Patient Simulator

Contec MS400 Multi-Parameter Patient Simulator

Regular price

R 17,897.99

Prices Include VAT

More about the Contec MS400 Multi-Parameter Patient Simulator

Description:

  • MS400 Multiparameter Simulator is a portable device, which can provide comprehensive physiological waveform to content general test and train requirement.
  • It can check the monitor rapidly near the bed, also can test the quality warranty of ECG equipment, monitor and remote therapy equipment.
  • At the same time, it can be used as the training of distinguishing from arrhythmia waveforms to the nurses.

Features:

  • 3.5-inch colour TFT touch-screen, 320*240 pixels, and friendly operation interface.
  • Display the output waveforms synchronously, which is convenient for user to compare with the test equipment.
  • It integrates the functions of SD socket interface; user can output the custom waveform by this device.
  • Built-in templates list to provide the waveform that is expressed by each preset sequence number, which is convenient for searching.
  • Two operation interfaces: Chinese and English.
  • Operate with keystroke and touch-screen expediently and rapidly.
  • Built-in 3.7V/4000mAh (Rechargeable alkaline battery).
  • Optical external power: AC 220V, 50Hz or AC 120V, 60Hz

ECG/Arrhythmia:
ECG:

  • Conventional: All leads have the same voltage with the II-lead as the reference
  • Amplitude: 0.5,1.0,1.5 and 2.0mV
  • The accuracy of Amplitude: ±2%
  • ECG Rate: 15,20,25,30,40,60,80,100,120,140,160,180,200,220,240,260,280,300,320,340 and 350 BPM
  • ECG artifacts: 50 or 60 Hz, muscle, baseline drift and breathing
  • The elevation of the ST segment: -0.8 mV to +0.8 mV, the step is 0.1 mV
  • The default: 80 BPM,1mV

Arrhythmia:

  • Atrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial
  • Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
  • Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular
  • Contraction (PVC) 6/min,
  • PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5
  • PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
  • Premature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PNC, Left
  • Ventricular Focus
  • PVC1, Early Left Ventricular Focus PVC1, Right Ventricular Focus PVC1, Early
  • Right
  • Ventricular Focus PVC1, R on T Left Ventricular Focus, R on T Right
  • Ventricular Focus, Multifocal PVC
  • Conduction Defects: First Degree Heart Block, Second Degree Heart Block,
  • Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch
  • Block

ECG Performance Testing:

  • ECG amplitude: 0.5,1.0,1.5 and 2.0mV
  • The accuracy of Amplitude: ±2%
  • Pulse: 30 and 60 BPM, the width of pulse wave is 60 ms
  • Square: 0.125 and 2.0 Hz
  • Triangle: 2.0 and 2.5 Hz
  • Sine: .0.5, 5, 10, 40, 50, 60 and 100 Hz
  • ECG Rate:15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240,
  • 260, 280, 300, 320, 340 and 350 BPM
  • The accuracy of ECG Rate: ±1%

Respiration:

  • Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIIN
  • Respiration Impedance: 0.2, 0.5, 1.0 and 3.0 B
  • Baseline Impedance:500,1000,1500 and 2000
  • Apnea: 12 s, 22 s, 32 s
  • ECG simulator with adjustable heart rate/12-lead output
  • 33 kinds of Arrhythmia waveforms
  • Pacemaker
  • Two IBP channels
  • Variety of respiratory impedance,apnea pauses (0 BrPM) of 12, 22 and 32 seconds.
  • Standard ECG calibration
  • Export square,triangle and sine with adjustable frequency

IBP:

  • The default: 00/00mmHg
  • Dynamic IBP

Channel 1: Artery 120/80mmHg

  • Radial 120/80mmHg
  • Left Ventricle 120/00mmHg
  • Right Ventricle 25/00mmHg

Channel 2: Artery 120/80mmHg

  • Radial 120/80mmHg
  • Left Ventricle 120/00mmHg
  • Right Atrium 15/10mmHg
  • Right Ventricle 25/00mmHg
  • Pulmonary Artery 25/10mmHg
  • Left Atrium 14/4mmHg

Static-Pressure Levels:

  • Channel 1: 0, 80, 160, 240, 320 and 400mmHg
  • Channel 2: 0, 50, 100, 150, 200 and 250mmHg

 

Lead time:

Our lead times are 5-7 working days excluding weekends, public holiday’s & shipping time with our courier.

Lead times on out of stock or special-order items 6-8 weeks / 8-10 weeks

PLEASE NOTE DUE TO UNFORSEEN ROAD OR AIR FREIGHT DELAYS PARECLES CAN BE DELAYED BY A FEW DAYS. 

*Please note pictures are mainly for illustration purposes, actual product and size may vary slightly*